The AMCI NEXUS PLS Controller integrates high-speed programmable limit switch functions with a direct network connection. These units operate independently from, yet communicate data and status to, the main system controller. Program files are downloaded for all output setpoint functions while operational data is available over the network. Typical applications are packaging machine controls, high-speed assembly, and food and beverage machine applications.
The NX3A1_ uses a single resolver transducer as the position sensor while the NX3M1_ uses an incremental encoder.
Both units have two modes of operation, Independent Mode and Group Mode, both of which feature speed compensation (Auto Advance). Configured using the Independent Mode, each output is independent of the others and has a corresponding input that is ANDed with the output.
Configured using the Group Mode, the outputs are combined into one of six groups. Each group is assigned an Operating Mode that condition how the outputs fire. This configuration replaces the ladder logic that you would typically have to write for such packaging functions as glue gun control or material sensing. In either mode, the programmable limit switch outputs are updated every 100microseconds.
NX3A1_: Programmable limit switch with 8 outputs and network connection
Price | $2,276/ea
NX3M1_: Programmable limit switch with 16 outputs and network connection
Price | $2,276/ea
Note: Pricing is US Domestic only
Consult the factory for availability
Contact SalesFunctionally, the AMCI NEXUS controllers and interfaces deliver the same level of PLC integration as their plug-in module counterparts, but with much more flexibility from a systems standpoint. Rather than limit these versatile products to one PLC brand or specific backplane, all units are Din-rail mountable and equipped with a network interface that allows connection to various controllers. AMCI NEXUS specialty I/O integrate with ANY network enabled PLC using Ethernet I/P, Modbus TCP/IP, Profinet, Profibus, ControlNet, or DeviceNet.
The flexibility of a NEXUS controls solution saves time and money, letting customers choose whatever PLC best meets their needs, or change PLCs without having to re-specify and repurchase plug-in modules. And because the NEXUS integrates via network communication, PLC platforms no longer restrict compatibility and integration.
NEXUS is compatible with any networked PLC
AMCI products are uniquely designed to provide the best PLC integration available. Unlike other products that require a separate software package for configuration or operation, AMCI's PLC-based products are programmed using your PLC's software - nothing new to buy or learn!
Our expertise with the leading PLC manufacturers (e.g. Allen-Bradley Schneider, GE, etc) is unmatched when it comes to high performance Specialty I/O, Position Sensing, and Motion Control technology.
AMCI's products program using your PLC's native software - nothing new to learn or buy!
AMCI Module | NX3A1_ | NX3M1_ |
---|---|---|
Network Availability | NX3A1A (ProfiNet) NX3A1C (ControlNet) NX3A1D (DeviceNet) NX3A1E (Ethernet IP) NX3A1P (Profibus) NX3A1T (Modbus TCP/IP) | NX3M1A (Profinet) NX3M1C (ControlNet) NX3M1D (DeviceNet) NX3M1E (Ethernet IP) NX3M1P (Profibus) NX3M1T (Modbus TCP/IP) |
Position sensor | resolver | incremental encoder |
Number of channels | 1 | |
Max. full scale count | 8,192 | 16,384 |
Number of I/O D=Direct B=Backplane RB=Relay Board | D=16 in B=na RB=8 out | |
Operationg modes: I=Independent G=Group | I = outputs function as a cam switch G = outputs combined and conditioned by a single input | |
Output update time | 200us | |
Tachometer update time | 504ms or 120ms | |
Transducer compatibility | H25 / HT-6 / HT-20 / HT-400 HT-20-(X) / R11X-J10/7 | AMCI Incremental DuraCoder |
Cable Requirements | CTL-X | na |
Input connector | Resolver Input Connector (1 per unit) AMCI Part # = MS-8 Phoenix Contact Part # = MSTB2.5/8-ST-5.08 One connector is included with the unit | Encoder Input Connector (1 per unit) AMCI Part # = MS-10 Phoenix Contact Part # = MSTB2.5/10-ST-5.08 One connector is included with the unit Notes: 1. The +24Vdc pin (pin 9) is directly connected to the +24Vdc pin on the Power Connector. 2. If your encoder operates from a 5Vdc supply, and draws less than 350mA, than it can be powered directly from pin 1 of the NX3M1X’s connector. |
Required hardware | RB-8 & CRP-X cable to use outputs #9-16 | |
Optional hardware | na |
AMCI makes buying PLC-based automation easy...our sales group will help you:
Contact AMCI Sales today:
860-585-1254
AMCI's sales team takes the hassle out of placing your order. We'll advise on product selection, alternatives, lead times, and present you with point of purchase options. Call (860) 585-1254 or email AMCI sales today!
AMCI's Matt Tellier describes Programmable Limit Switch (PLS) Technology including, What is a P...
Watch NowThe Basic purpose of a limit switchis to switch discrete outputs on or off based on the positio...
Read the Tutorial