The concept of a resolver interface is nothing new to the industrial marketplace. The same cannot be said of AMCI's NEXUS NX2A4_; arguably the most versatile resolver interface available today.
Engineered to provide absolute position and velocity data directly to the network, the four resolver channels can be configured three different ways: (4) single resolver inputs, (2) dual resolver multiturn inputs, and (2) single resolver inputs + (1) dual resolver multiturn input.
With 13-bit resolution for single resolver applications and 20-bit resolution for dual resolver applications, the NX2A4_can be used in applications ranging from metal stamping to high speed assembly and to overhead cranes. Whether your application calls for a single-turn resolver, multi-turn resolver, or some combination of both, the NEXUS resolver interface is the solution.
In addition to the above functionality, the NX2A4_ also has a brake input that provides stopping time and brake applied position to the network. This information can be used for brake wear monitoring thereby ensuring operator safety.
NX2A4_: Two-channel resolver interface with network connection
Price | $2,619/ea
Note: Pricing is US Domestic only
Consult the factory for availability
Contact SalesFunctionally, the AMCI NEXUS controllers and interfaces deliver the same level of PLC integration as their plug-in module counterparts, but with much more flexibility from a systems standpoint. Rather than limit these versatile products to one PLC brand or specific backplane, all units are Din-rail mountable and equipped with a network interface that allows connection to various controllers. AMCI NEXUS specialty I/O integrate with ANY network enabled PLC using Ethernet I/P, Modbus TCP/IP, Profibus, ControlNet, or DeviceNet.
The flexibility of a NEXUS controls solution saves time and money, letting customers choose whatever PLC best meets their needs, or change PLCs without having to re-specify and repurchase plug-in modules. And because the NEXUS integrates via network communication, PLC platforms no longer restrict compatibility and integration.
NEXUS is compatible with any networked PLC
AMCI products are uniquely designed to provide the best PLC integration available. Unlike other products that require a separate software package for configuration or operation, AMCI's PLC-based products are programmed using your PLC's software - nothing new to buy or learn!
Our expertise with the leading PLC manufacturers (e.g. Allen-Bradley Schneider, GE, etc) is unmatched when it comes to high performance Specialty I/O, Position Sensing, and Motion Control technology.
AMCI's products program using your PLC's native software - nothing new to learn or buy!
AMCI Module | NX2A4_ (single resolver config.) | NX2A4_ (dual resolver config.) |
---|---|---|
Network Availability | NX2A4A (Profinet) NX2A4C (ControlNet) NX2A4D (DeviceNet) NX2A4E (Ethernet IP) NX2A4E2 (Ethernet IP, Modbus-TCP/IP, & Profinet) NX2A4P (Profibus) NX2A4T (Modbus TCP/IP) | |
Position sensor | resolver | |
Number of channels | 4 maximum | 2 maximum |
Maximum full scale count | 8192 counts for single resolver transducers | 4096 counts/turn for dual resolver multi-turn transducers |
Position update time | 200us | |
DC supply requirements | 500 mA @ 24Vdc | |
Transducer compatibility | H25 / HT-6 / HT-20 / HT-400 / HT-20-(X) / R11X-J10/7 | HTT-20 / HTT-400 / HTT-425 |
Cable requirements | CTL-X | CML-X |
Resolver input connectors (2 per unit) | AMCI Part # = MS-8 Phoenix Contact Part # = MSTB2.5/8-ST-5.08 Two connectors are included with the unit Each connector has three possible wiring configurations; one Single Turn Resolver, Two Single Turn Resolvers, or One Multiturn Resolver One Single Turn Resolver (One CTL-X cable) Two Single Turn Resolvers (Two CTL-X cables) One Multiturn Resolver (One CML-X cable) | |
Required hardware | na | |
Optional hardware | na |
AMCI Module | NX2A4_ (single resolver config.) | NX2A4_ (dual resolver config.) |
---|---|---|
Network Availability | NX2A4A (Profinet) NX2A4C (ControlNet) NX2A4D (DeviceNet) NX2A4E (Ethernet IP) NX2A4E2 (Ethernet IP, Modbus-TCP/IP, & Profinet) NX2A4P (Profibus) NX2A4T (Modbus TCP/IP) | |
Position sensor | resolver | |
Number of channels | 4 maximum | 2 maximum |
Maximum full scale count | 8192 counts for single resolver transducers | 4096 counts/turn for dual resolver multi-turn transducers |
Position update time | 200us | |
DC supply requirements | 500 mA @ 24Vdc | |
Transducer compatibility | H25 / HT-6 / HT-20 / HT-400 / HT-20-(X) / R11X-J10/7 | HTT-20 / HTT-400 / HTT-425 |
Cable requirements | CTL-X | CML-X |
Resolver input connectors (2 per unit) | AMCI Part # = MS-8 Phoenix Contact Part # = MSTB2.5/8-ST-5.08 Two connectors are included with the unit Each connector has three possible wiring configurations; one Single Turn Resolver, Two Single Turn Resolvers, or One Multiturn Resolver One Single Turn Resolver (One CTL-X cable) Two Single Turn Resolvers (Two CTL-X cables) One Multiturn Resolver (One CML-X cable) | |
Required hardware | na | |
Optional hardware | na |
AMCI makes buying PLC-based automation easy...our sales group will help you:
Contact AMCI Sales today:
860-585-1254
AMCI's sales team takes the hassle out of placing your order. We'll advise on product selection, alternatives, lead times, and present you with point of purchase options. Call (860) 585-1254 or email AMCI sales today!
When discussing resolvers, people often interchange terms such as: encoders, rotary position se...
Read the TutorialAMCI’s wide selection of resolver transducers, resolver interfaces for PLC based systems, and r...
Watch Now